LSP241 · Microscope and optical tweezers research instruments · Microscopic imaging and particle research
Reusable modules

Alignment of excitation beam with pinhole fiducial

Facing the confocal light path, taking the target surface light point position as the observation route, the conjugate surface light point offset is intended to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceConfocal light path
Measure routeXY · Target surface light spot position
Ability GradingReusable modules
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.

Business tasks and intended output

target audience
Confocal light path: target spot position
pseudo output
Conjugate surface light point offset
Applicable conditions
Actual axial resolution requires separate measurement of fluorescent samples
priority
General extension. Verification needs to be completed according to the listed optical conditions, calibration and samples.

Imaging input and algorithm routing

Imaging and device conditions

Fix the camera and target surface, record the exposure and gain, and cover the light spot and background in the field of view. Microscopes, relay sampling and wavelength-adapted cameras

XY · Target surface light spot position

Fix the camera and target surface, record exposure and gain, and cover the light spot and background in the field of view

  • A101Adaptive threshold laser spot grayscale centroid
  • A107Laser spot quality and usability diagnostics
  • A112Laser spot two-dimensional repeatability and coverage ellipse

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Reusable modules

Existing modules can be used as hosts

Existing light point positioning, quality diagnosis or statistical modules can be used as the main calculation basis; ROI, calibration, threshold and interface verification still need to be completed by device.

Gaps in this scenario:ROI, ruler/plane calibration and reference point definition are required; only the two-dimensional position of the target surface can be directly observed. The actual axial resolution needs to be measured separately on fluorescent samples. Particle image positioning is an algorithm migration and the image model must be re-verified.

Route-level gaps:Requires ROI, ruler/plane calibration and reference point definition; can only directly observe the two-dimensional position of the target surface

"Reusable modules" only describe the relative development volume and do not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Test independently with a two-dimensional displacement stage and a fixed reference point, reporting center error P95, missed detections and false detections. Microsphere stage, microscopic ruler and independent positioning reference

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S20 · Original factory/scientific research institution/original paper

Radial Symmetry Center Original Paper

Sub-pixel center positioning of approximately radially symmetric targets

Verification date: 2026-10-24

View original public information →
LS-S21 · Original factory/scientific research institution/original paper

Research on position calibration of optical tweezers camera

Limited particle position detection and the impact of exposure and sampling on calibration

Verification date: 2026-10-24

View original public information →
LS-S30 · Original factory/scientific research institution/original paper

Ophir small beam measurement

Optical conditions in small beam near-field, far-field and mode field measurements

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Alignment of excitation beam with pinhole fiducial

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.