Hamar Machine Axis Alignment Instructions
Geometric alignment of linear axis, rotary axis and reference target
Verification date: 2026-10-24
View original public information →Facing the marine steering gear test bench, the angle of the reflective optical lever is used as the observation route, and the angle command and target point mapping are planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
Fix the incident light and reflector, and calibrate the corresponding relationship between the camera/receiving screen and the angle stage. Manufacturing or testing stations with fixed reference targets and independent pose/displacement datums
Fix the incident light and reflector, and calibrate the corresponding relationship between the camera/receiving screen and the angle stage
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.
Gaps in this scenario:Optical lever geometry, reflection double angle relationship and incident point movement compensation are required; mirror angle and target translation must be separated. The load and return difference are tested according to working conditions. It is only used for manufacturing measurement and testing, and does not directly bear the responsibility for operational safety judgments.
Route-level gaps:Optical lever geometry, reflection double angle relationship and incident point movement compensation are required; mirror angle and target translation must be separated
"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.
Use an independent angle stage/autocollimator to conduct bidirectional and multi-attitude tests, and report the angle error and return difference. Special gauge, three-coordinate or standard motion table cross test
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Geometric alignment of linear axis, rotary axis and reference target
Verification date: 2026-10-24
View original public information →Hole target adapter aligned with reference axis
Verification date: 2026-10-24
View original public information →Active point triangulation, scanned geometry and error propagation
Verification date: 2026-10-24
View original public information →Reflection point calibration of steering gear axis angle
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357