Hamar Machine Axis Alignment Instructions
Geometric alignment of linear axis, rotary axis and reference target
Verification date: 2026-10-24
View original public information →Facing the bogie tooling, taking the light spot position on the target surface as the observation route, the target hole center deviation is intended to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
Fix the camera and target surface, record the exposure and gain, and cover the light spot and background in the field of view. Manufacturing or testing stations with fixed reference targets and independent pose/displacement datums
Fix the camera and target surface, record exposure and gain, and cover the light spot and background in the field of view
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
Existing light point positioning, quality diagnosis or statistical modules can be used as the main calculation basis; ROI, calibration, threshold and interface verification still need to be completed by device.
Gaps in this scenario:ROI, ruler/plane calibration and reference point definition are required; only the two-dimensional position of the target surface can be directly observed. The hole system tooling needs to be calibrated. It is only used for manufacturing measurement and testing, and does not directly bear the responsibility for operational safety judgments.
Route-level gaps:Requires ROI, ruler/plane calibration and reference point definition; can only directly observe the two-dimensional position of the target surface
"Reusable modules" only describe the relative development volume and do not constitute a commitment to accuracy, tempo, stability or delivery time.
Test independently with a two-dimensional displacement stage and a fixed reference point, reporting center error P95, missed detections and false detections. Special gauge, three-coordinate or standard motion table cross test
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Geometric alignment of linear axis, rotary axis and reference target
Verification date: 2026-10-24
View original public information →Hole target adapter aligned with reference axis
Verification date: 2026-10-24
View original public information →Active point triangulation, scanned geometry and error propagation
Verification date: 2026-10-24
View original public information →Bogie mounting hole axis alignment
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357