LSP146 · Robot end and tooling · General assembly three-dimensional measurement and equipment status
Need to add new core

Joint external parameter study of camera and emission axis

For the robot camera laser combination, the lattice three-dimensional positioning is used as the observation route, and the intended output point corresponds to the geometric residual. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceRobot Camera Laser Combo
Measure routePOSE·lattice three-dimensional positioning
Ability GradingNeed to add new core
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.

Business tasks and intended output

target audience
Robot camera laser combination: lattice three-dimensional positioning
pseudo output
Point correspondence and geometric residuals
Applicable conditions
Hand-eye and point-ray calibration cores need to be added
priority
Special development. The measurement/control core needs to be supplemented and verified according to the special project approval

Imaging input and algorithm routing

Imaging and device conditions

Numbered projection points or targets, multi-view/known target geometry, and camera calibration. Fixed target, robot pose log and synchronized camera

POSE·lattice three-dimensional positioning

Numbered projection points or targets, multi-view/known target geometry and camera calibration

  • A39Multi-view checkerboard camera calibration
  • A40Image and point dedistortion
  • A102Multi-laser spot connected domain candidate extraction
  • A108One-to-one matching of multi-laser spot reference bits
  • A111laser spot pixel to camera view angle conversion

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Need to add new core

Need to add core computing

Light point extraction can only be used as an observation front-end, and core capabilities such as three-dimensional reconstruction, closed-loop control, wavefront or physical quantity inversion need to be developed and verified separately.

Gaps in this scenario:Three-dimensional correspondence, PnP/triangulation, SE(3) external parameters and hand-eye calibration need to be added; A42 is only two-dimensional. The hand-eye and point-ray calibration cores need to be added. Two-dimensional target surface observation and complete three-dimensional robot calibration are defined separately.

Route-level gaps:Three-dimensional correspondence, PnP/triangulation, SE(3) external parameters and hand-eye calibration need to be added; A42 is only two-dimensional

"New cores required" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Test occlusion, symmetry and degraded poses against a 3D/robot or 6DOF reference platform. Independent spatial reference and repeated trajectories, layered testing by attitude

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S03 · Original factory/scientific research institution/original paper

Micro-Epsilon Laser Triangulation Principle

Transmitting, receiving imaging and distance measurement after calibration

Verification date: 2026-10-24

View original public information →
LS-S17 · Original factory/scientific research institution/original paper

Holo/Or structured light principle

The principle of using known projection patterns and geometric deformations for measurement

Verification date: 2026-10-24

View original public information →
LS-S26 · Original factory/scientific research institution/original paper

NIST 3D Imaging Technology Description

Active point triangulation, scanned geometry and error propagation

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Joint external parameter study of camera and emission axis

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.