LSP296 · Medical and experimental equipment manufacturing · Medical equipment and medical consumables
Reusable modules

Laser reference retest of chip clamping position

Facing the microfluidic detector fixture, the light spot position on the target surface is used as the observation route, and the clamping rounds and XY difference are planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceMicrofluidic detector fixture
Measure routeXY · Target surface light spot position
Ability GradingReusable modules
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.
Regulated industry boundaries:This page only discusses the candidate tasks of geometry, position or motion measurement in the manufacturing process of medical and experimental equipment. It does not introduce specific medical device products, and does not provide conclusions on clinical uses or clinical effects. If subsequent pages are associated with specific registered/filed medical devices, scope of application or performance, advertising review and release approval should be completed separately based on valid registration/filing information.

Business tasks and intended output

target audience
Microfluidic detector fixture: light spot position on target surface
pseudo output
Clamping round and XY difference
Applicable conditions
Detection sensitivity and biological results are subject to separate acceptance
priority
General extension. Verification needs to be completed according to the listed optical conditions, calibration and samples.

Imaging input and algorithm routing

Imaging and device conditions

Fix the camera and target surface, record the exposure and gain, and cover the light spot and background in the field of view. Target surfaces and displacement datums in manufacturing/service stations, non-human exposure

XY · Target surface light spot position

Fix the camera and target surface, record exposure and gain, and cover the light spot and background in the field of view

  • A101Adaptive threshold laser spot grayscale centroid
  • A107Laser spot quality and usability diagnostics
  • A112Laser spot two-dimensional repeatability and coverage ellipse

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Reusable modules

Existing modules can be used as hosts

Existing light point positioning, quality diagnosis or statistical modules can be used as the main calculation basis; ROI, calibration, threshold and interface verification still need to be completed by device.

Gaps in this scenario:ROI, ruler/plane calibration and reference point definition are required; only the two-dimensional position of the target surface can be directly observed. Detection sensitivity and biological results are subject to separate acceptance checks. It only measures device geometry or motion and does not form conclusions about diagnostic or therapeutic performance.

Route-level gaps:Requires ROI, ruler/plane calibration and reference point definition; can only directly observe the two-dimensional position of the target surface

"Reusable modules" only describe the relative development volume and do not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Test independently with a two-dimensional displacement stage and a fixed reference point, reporting center error P95, missed detections and false detections. Comparison of mechanical gauges, displacement tables and equipment-specific test procedures

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S03 · Original factory/scientific research institution/original paper

Micro-Epsilon Laser Triangulation Principle

Transmitting, receiving imaging and distance measurement after calibration

Verification date: 2026-10-24

View original public information →
LS-S09 · Original factory/scientific research institution/original paper

Duma Beam Position and Optical Adjustment Application

Application categories for beam position, optical setup and spot shape

Verification date: 2026-10-24

View original public information →
LS-S19 · Original factory/scientific research institution/original paper

How Nanosurf AFM works

Reflected light spot, cantilever beam deflection and sensitivity calibration

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Laser reference retest of chip clamping position

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.