LSP294 · Medical and experimental equipment manufacturing · Medical equipment and medical consumables
Partially reusable

Tooling inspection of projected lattice geometry

For the dental scanning optical prototype, the separation light point array comparison is used as the observation route, and the residual error between the point distance and the reference point is planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceDental scanning optical prototype
Measure routeARRAY·Separate spot array comparison
Ability GradingPartially reusable
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.
Regulated industry boundaries:This page only discusses the candidate tasks of geometry, position or motion measurement in the manufacturing process of medical and experimental equipment. It does not introduce specific medical device products, and does not provide conclusions on clinical uses or clinical effects. If subsequent pages are associated with specific registered/filed medical devices, scope of application or performance, advertising review and release approval should be completed separately based on valid registration/filing information.

Business tasks and intended output

target audience
Dental scanning optical prototype: separation light spot array comparison
pseudo output
Point distance and reference point residual
Applicable conditions
Three-dimensional oral reconstruction core needs to be added
priority
General extension. Verification needs to be completed according to the listed optical conditions, calibration and samples.

Imaging input and algorithm routing

Imaging and device conditions

Separate and numberable multiple light spots, fixed receiving plane and field of view. Target surfaces and displacement datums in manufacturing/service stations, non-human exposure

ARRAY·Separate spot array comparison

Separate and numberable multiple light spots, fixed receiving plane and field of view

  • A102Multi-laser spot connected domain candidate extraction
  • A105Laser spot second moment and main axis diameter
  • A107Laser spot quality and usability diagnostics
  • A108One-to-one matching of multi-laser spot reference bits
  • A112Laser spot two-dimensional repeatability and coverage ellipse

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Partially reusable

Requires calibration, synchronization or integration

The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.

Gaps in this scenario:Point sequence numbering, local ROI, crosstalk and occlusion processing are required; A108 only matches by distance in the same coordinate system. The core of three-dimensional oral reconstruction needs to be added. It only measures device geometry or motion and does not form conclusions about diagnostic or therapeutic performance.

Route-level gaps:Point sequence numbering, local ROI, crosstalk and occlusion processing are required; A108 only matches by distance in the same coordinate system

"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Verify point counts, match rates, and mismatches using known lattice and artificial defect/overlap/scrambling data. Comparison of mechanical gauges, displacement tables and equipment-specific test procedures

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S03 · Original factory/scientific research institution/original paper

Micro-Epsilon Laser Triangulation Principle

Transmitting, receiving imaging and distance measurement after calibration

Verification date: 2026-10-24

View original public information →
LS-S09 · Original factory/scientific research institution/original paper

Duma Beam Position and Optical Adjustment Application

Application categories for beam position, optical setup and spot shape

Verification date: 2026-10-24

View original public information →
LS-S19 · Original factory/scientific research institution/original paper

How Nanosurf AFM works

Reflected light spot, cantilever beam deflection and sensitivity calibration

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Tooling inspection of projected lattice geometry

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.