LSP295 · Medical and experimental equipment manufacturing · Medical equipment and medical consumables
Partially reusable

Observation of axis pendulum of low-speed turntable reflection target

Facing the centrifuge test turntable, the light spot timing and drift are used as the observation route, and the angle synchronization trajectory is planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceCentrifuge test turntable
Measure routeTIME · Light spot timing and drift
Ability GradingPartially reusable
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.
Regulated industry boundaries:This page only discusses the candidate tasks of geometry, position or motion measurement in the manufacturing process of medical and experimental equipment. It does not introduce specific medical device products, and does not provide conclusions on clinical uses or clinical effects. If subsequent pages are associated with specific registered/filed medical devices, scope of application or performance, advertising review and release approval should be completed separately based on valid registration/filing information.

Business tasks and intended output

target audience
Centrifuge test turret: light spot timing and drift
pseudo output
Angle synchronized trajectory
Applicable conditions
High-speed rotor conditions require additional bandwidth selection
priority
General extension. Verification needs to be completed according to the listed optical conditions, calibration and samples.

Imaging input and algorithm routing

Imaging and device conditions

Global shutter or known readout timing, saves timestamps, and exposures adapted to frequency of motion. Target surfaces and displacement datums in manufacturing/service stations, non-human exposure

TIME · Light spot timing and drift

Global shutter or known readout timing, saves timestamps, exposures fit to frequency of motion

  • A22Kalman filter
  • A25Welch power spectrum estimation
  • A72Hampel median absolute deviation anomaly filtering
  • A101Adaptive threshold laser spot grayscale centroid
  • A107Laser spot quality and usability diagnostics
  • A112Laser spot two-dimensional repeatability and coverage ellipse

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Partially reusable

Requires calibration, synchronization or integration

The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.

Gaps in this scenario:Requires sampling rate/exposure verification, time synchronization and reference target camera motion compensation; not a substitute for laser Doppler vibrometers. High-speed rotor operating conditions require additional bandwidth selection. It only measures device geometry or motion and does not form conclusions about diagnostic or therapeutic performance.

Route-level gaps:Requires sampling rate/exposure verification, time synchronization and reference target camera motion compensation; not a substitute for laser Doppler vibrometers

"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Verify aliasing, phase, drift and frame loss with a known frequency shaker or encoder comparison. Comparison of mechanical gauges, displacement tables and equipment-specific test procedures

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S03 · Original factory/scientific research institution/original paper

Micro-Epsilon Laser Triangulation Principle

Transmitting, receiving imaging and distance measurement after calibration

Verification date: 2026-10-24

View original public information →
LS-S09 · Original factory/scientific research institution/original paper

Duma Beam Position and Optical Adjustment Application

Application categories for beam position, optical setup and spot shape

Verification date: 2026-10-24

View original public information →
LS-S19 · Original factory/scientific research institution/original paper

How Nanosurf AFM works

Reflected light spot, cantilever beam deflection and sensitivity calibration

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Observation of axis pendulum of low-speed turntable reflection target

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.