Micro-Epsilon Laser Triangulation Principle
Transmitting, receiving imaging and distance measurement after calibration
Verification date: 2026-10-24
View original public information →Facing the wafer handling fixture, the point laser triangular displacement is used as the observation route, and the height difference of the support point is intended to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
By fixing the laser emission axis and the receiving camera baseline, separable light spots can be formed on the target surface. Fixed baseline point laser receiving head and calibration Z platform
By fixing the laser emission axis and the receiving camera baseline, the target surface can form separable light spots.
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.
Gaps in this scenario:It is necessary to add point laser ray intersection or one-dimensional nonlinear distance calibration adaptation; A97 only has a linear area, and A21 is a laser plane interface. Formal flatness evaluation core needs to be added. The surface reflection of the actual machine and the small measuring range determine whether the effective point can be collected.
Route-level gaps:It is necessary to add point laser ray intersection or one-dimensional nonlinear distance calibration adaptation; A97 is only in the linear area, and A21 is the laser plane interface
"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.
Use gauge blocks and stages to cover range and surface conditions and independently report physical error, repeatability, and speckle effects. Gauge block, microscopic height gauge and independent assembly sample comparison
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Transmitting, receiving imaging and distance measurement after calibration
Verification date: 2026-10-24
View original public information →Industrial height, distance and position measurement categories
Verification date: 2026-10-24
View original public information →Active point triangulation, scanned geometry and error propagation
Verification date: 2026-10-24
View original public information →High consistency check of fixture support surfaces
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357