Wenge STM32H743 and OV9281 light point positioning case
Embedded image acquisition, adaptive threshold and spot centroid public functions
Verification date: 2026-10-24
View original public information →Facing the optical lever experimental instrument, taking the angle of the reflective optical lever as the observation route, the curve of the stage angle and target displacement is planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
Fix the incident light and reflector, and calibrate the corresponding relationship between the camera/receiving screen and the angle stage. Closed low-power teaching light path, standard target and known motion table
Fix the incident light and reflector, and calibrate the corresponding relationship between the camera/receiving screen and the angle stage
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.
Gaps in this scenario:Optical lever geometry, reflection double angle relationship and incident point movement compensation are required; mirror angle and target translation must be separated. The entrance geometry and effective arm length must be measured. Teaching demonstration data should indicate model, sampling and units
Route-level gaps:Optical lever geometry, reflection double angle relationship and incident point movement compensation are required; mirror angle and target translation must be separated
"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.
Use an independent angle stage/autocollimator to conduct bidirectional and multi-attitude tests, and report the angle error and return difference. Double verification of analytical composite images and physical bench
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Embedded image acquisition, adaptive threshold and spot centroid public functions
Verification date: 2026-10-24
View original public information →Light point position, triangular ranging and position-sensitive detection principles; PSD hardware performance is not transferred to camera implementation
Verification date: 2026-10-24
View original public information →Relationship between diffraction order, angle, wavelength and grating period
Verification date: 2026-10-24
View original public information →Relationship between source size, focal length and divergence angle
Verification date: 2026-10-24
View original public information →Calibration verification of reflection double angle relationship
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357