Wenge STM32H743 and OV9281 light point positioning case
Embedded image acquisition, adaptive threshold and spot centroid public functions
Verification date: 2026-10-24
View original public information →Facing the wave optics experimental instrument, the diffraction order position inversion is used as the observation route, and the order coordinates and spacing are planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
A far-field device in which one of the wavelengths or periods, the diffraction order, and the direction of incidence are known. Closed low-power teaching light path, standard target and known motion table
A far-field device in which one of the wavelengths or periods, the diffraction order, and the direction of incidence are known
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
Light point extraction can only be used as an observation front-end, and core capabilities such as three-dimensional reconstruction, closed-loop control, wavefront or physical quantity inversion need to be developed and verified separately.
Gaps in this scenario:It is necessary to add grating equation/diffraction model, order identification and wavelength temperature drift compensation. The grating and wavelength reference need to be known. Teaching demonstration data should indicate model, sampling and units
Route-level gaps:Need to add grating equation/diffraction model, order identification and wavelength temperature drift compensation
"New cores required" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.
Cross-test with standard grating and independent wavelength/angle reference to troubleshoot order ambiguities. Double verification of analytical composite images and physical bench
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Embedded image acquisition, adaptive threshold and spot centroid public functions
Verification date: 2026-10-24
View original public information →Light point position, triangular ranging and position-sensitive detection principles; PSD hardware performance is not transferred to camera implementation
Verification date: 2026-10-24
View original public information →Relationship between diffraction order, angle, wavelength and grating period
Verification date: 2026-10-24
View original public information →Relationship between source size, focal length and divergence angle
Verification date: 2026-10-24
View original public information →Automatic reading of multi-order diffraction spots
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357