LSP260 · Materials and chemical photothermal research · Chemical droplet wetting and interface
Need to add new core

Comparative study on thermal response before and after coating

Facing the coating substrate, using the deflection of the photothermal probe as the observation route, the simulated output modulates the deflection difference. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/Devicecoating substrate
Measure routeTHERMAL · Photothermal probe deflection
Ability GradingNeed to add new core
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.

Business tasks and intended output

target audience
Coated Substrate: Photothermal Probe Deflection
pseudo output
modulation deflection difference
Applicable conditions
The film thickness cannot be directly determined by a single frequency signal.
priority
Special development. The measurement/control core needs to be supplemented and verified according to the special project approval

Imaging input and algorithm routing

Imaging and device conditions

The pump/probe optical path, modulation reference and thermal boundaries are known, and the samples cover the modulation frequency. Pump/probe optical path, synchronized modulation and controlled temperature environment

THERMAL · Photothermal probe deflection

The pump/probe optical path, modulation reference and thermal boundaries are known, and the sampling covers the modulation frequency

  • A74short time Fourier transform STFT
  • A101Adaptive threshold laser spot grayscale centroid
  • A103Logarithmic quadratic surface sub-pixel spot center
  • A107Laser spot quality and usability diagnostics
  • A112Laser spot two-dimensional repeatability and coverage ellipse

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Need to add new core

Need to add core computing

Light point extraction can only be used as an observation front-end, and core capabilities such as three-dimensional reconstruction, closed-loop control, wavefront or physical quantity inversion need to be developed and verified separately.

Gaps in this scenario:New phase locking/thermal diffusion/refraction models and physical property parameter inversion need to be added; image deflection does not directly give thermal conductivity or absorptivity. The film thickness cannot be determined directly from a single frequency signal. All physical property outputs are inversions to be developed and are not directly replaced by displacements.

Route-level gaps:New phase locking/thermal diffusion/refraction models and physical property parameter inversion need to be added; image deflection does not directly provide thermal conductivity or absorptivity

"New cores required" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Verify the inversion using reference materials and independent thermal analyzers, varying frequency, beam offset, and boundary conditions. Reference materials, blank samples and independent physical property instrument comparison

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S22 · Original factory/scientific research institution/original paper

IBM Photothermal Deflectometry Research

The principle of probe beam deflection caused by refractive index gradient

Verification date: 2026-10-24

View original public information →
LS-S27 · Original factory/scientific research institution/original paper

NIST blue light triangulation study near flame

Displacement measurements and thermal gradient effects in specific fire tests, without extrapolation of values

Verification date: 2026-10-24

View original public information →
LS-S28 · Original factory/scientific research institution/original paper

Research on Speckle Uncertainty of Laser Triangulation

Effect of speckle on position and distance uncertainty

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Comparative study on thermal response before and after coating

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.