LSP125 · Plastic Rubber and Mold · Plastic and Injection Molding
Need to add new core

Point scanning study on loading deflection of membrane surface

Facing the elastic diaphragm, the point scanning three-dimensional topography is used as the observation route, and the off-plane displacement of the specified area is intended to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/Deviceelastic diaphragm
Measure routeSCAN·Point scanning 3D topography
Ability GradingNeed to add new core
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.

Business tasks and intended output

target audience
Elastic diaphragm: point scanning 3D topography
pseudo output
Displacement of specified area from plane
Applicable conditions
Film thickness and boundary conditions need to be measured separately
priority
Special development. The measurement/control core needs to be supplemented and verified according to the special project approval

Imaging input and algorithm routing

Imaging and device conditions

Scanning mechanism with encoder, point laser transceiver geometry and synchronized images. Material samples and non-contact tooling of different colors/transmittances

SCAN·Point scanning 3D topography

Scanning mechanism with encoder, point laser transceiver geometry and synchronized images

  • A41Three-dimensional point set orthogonal plane fitting
  • A101Adaptive threshold laser spot grayscale centroid
  • A103Logarithmic quadratic surface sub-pixel spot center
  • A107Laser spot quality and usability diagnostics
  • A111laser spot pixel to camera view angle conversion

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Need to add new core

Need to add core computing

Light point extraction can only be used as an observation front-end, and core capabilities such as three-dimensional reconstruction, closed-loop control, wavefront or physical quantity inversion need to be developed and verified separately.

Gaps in this scenario:It is necessary to add new point triangulation intersection, scanning coordinate fusion, surface reconstruction and shape and position evaluation; A41 only fits existing three-dimensional points. Film thickness and boundary conditions need to be measured separately. Material optical properties need to be included in calibration and failure conditions

Route-level gaps:It is necessary to add new point triangulation intersection, scanning coordinate fusion, surface reconstruction and shape and position evaluation; A41 only fits existing three-dimensional points.

"New cores required" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Use a known step/contour sample to perform a blind test with a CMM or profiler to verify the missing area and scanning step distance. Standard parts and contact gauges are crossed to test different surface conditions

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S03 · Original factory/scientific research institution/original paper

Micro-Epsilon Laser Triangulation Principle

Transmitting, receiving imaging and distance measurement after calibration

Verification date: 2026-10-24

View original public information →
LS-S04 · Original factory/scientific research institution/original paper

Micro-Epsilon displacement applications

Industrial height, distance and position measurement categories

Verification date: 2026-10-24

View original public information →
LS-S05 · Original factory/scientific research institution/original paper

Micro-Epsilon Thickness Application

Displacement sensor combination thickness measurement; different measurement principles should be selected separately

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Point scanning study on loading deflection of membrane surface

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.