LSP124 · Plastic Rubber and Mold · Plastic and Injection Molding
Partially reusable

Light point displacement observation of opening and closing stroke

Facing the mold slider, using the point laser triangular displacement as the observation route, the displacement curve and end point difference are planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceMold slider
Measure routeTRI·Point laser triangular displacement
Ability GradingPartially reusable
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.

Business tasks and intended output

target audience
Mold slider: point laser triangular displacement
pseudo output
Displacement curve and end point difference
Applicable conditions
Oil stains and obstructions should be marked as invalid
priority
General extension. Verification needs to be completed according to the listed optical conditions, calibration and samples.

Imaging input and algorithm routing

Imaging and device conditions

By fixing the laser emission axis and the receiving camera baseline, separable light spots can be formed on the target surface. Material samples and non-contact tooling of different colors/transmittances

TRI·Point laser triangular displacement

By fixing the laser emission axis and the receiving camera baseline, the target surface can form separable light spots.

  • A97Weighted least squares linear calibration
  • A100First-order sensitivity uncertainty propagation
  • A101Adaptive threshold laser spot grayscale centroid
  • A103Logarithmic quadratic surface sub-pixel spot center
  • A107Laser spot quality and usability diagnostics

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Partially reusable

Requires calibration, synchronization or integration

The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.

Gaps in this scenario:It is necessary to add point laser ray intersection or one-dimensional nonlinear distance calibration adaptation; A97 only has a linear area, and A21 is a laser plane interface. Oil stains and obstructions should be marked as invalid. Material optical properties need to be included in calibration and failure conditions

Route-level gaps:It is necessary to add point laser ray intersection or one-dimensional nonlinear distance calibration adaptation; A97 is only in the linear area, and A21 is the laser plane interface

"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Use gauge blocks and stages to cover range and surface conditions and independently report physical error, repeatability, and speckle effects. Standard parts and contact gauges are crossed to test different surface conditions

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S03 · Original factory/scientific research institution/original paper

Micro-Epsilon Laser Triangulation Principle

Transmitting, receiving imaging and distance measurement after calibration

Verification date: 2026-10-24

View original public information →
LS-S04 · Original factory/scientific research institution/original paper

Micro-Epsilon displacement applications

Industrial height, distance and position measurement categories

Verification date: 2026-10-24

View original public information →
LS-S05 · Original factory/scientific research institution/original paper

Micro-Epsilon Thickness Application

Displacement sensor combination thickness measurement; different measurement principles should be selected separately

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Light point displacement observation of opening and closing stroke

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.