LSP113 · Cable yarns and elongated parts · Cable connectors and electrical components
Partially reusable

Point displacement sampling of the outer diameter of both sides of the cable

Facing the cable sheath, using the bilateral/reference surface differential measurement as the observation route, it is planned to output the bilateral spacing candidates. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceCable jacket
Measure routeTHICK · Bilateral/reference surface differential measurement
Ability GradingPartially reusable
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.

Business tasks and intended output

target audience
Cable jacket: differential measurement on both sides/reference surface
pseudo output
Candidates for bilateral spacing
Applicable conditions
The eccentric trajectory and outer diameter models need to be added
priority
General extension. Verification needs to be completed according to the listed optical conditions, calibration and samples.

Imaging input and algorithm routing

Imaging and device conditions

Synchronized bilateral point displacement heads, or single head with a known stable reference plane. Fine light spot, suitable numerical aperture, stable guide mechanism

THICK · Bilateral/reference surface differential measurement

Synchronous bilateral point displacement heads, or single head with a known stable reference surface

  • A97Weighted least squares linear calibration
  • A100First-order sensitivity uncertainty propagation
  • A101Adaptive threshold laser spot grayscale centroid
  • A103Logarithmic quadratic surface sub-pixel spot center
  • A107Laser spot quality and usability diagnostics

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Partially reusable

Requires calibration, synchronization or integration

The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.

Gaps in this scenario:Point laser distance calibration, collinearity/synchronization and reference spacing models on both sides are required; the height of a single point is not directly equal to the thickness. The eccentric trajectory and outer diameter models need to be added. Minimum target size is determined by actual spot and imaging resolution

Route-level gaps:Point laser distance calibration, collinearity/synchronization and reference spacing models on both sides are required; the height of a single point is not directly equal to the thickness

"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Use standard thick slices and warped samples to compare, and change the inclination angle and motion phase to check the differential error. Microscopic measuring tool and standard wire/rod comparison, control speed and angle

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S03 · Original factory/scientific research institution/original paper

Micro-Epsilon Laser Triangulation Principle

Transmitting, receiving imaging and distance measurement after calibration

Verification date: 2026-10-24

View original public information →
LS-S05 · Original factory/scientific research institution/original paper

Micro-Epsilon Thickness Application

Displacement sensor combination thickness measurement; different measurement principles should be selected separately

Verification date: 2026-10-24

View original public information →
LS-S28 · Original factory/scientific research institution/original paper

Research on Speckle Uncertainty of Laser Triangulation

Effect of speckle on position and distance uncertainty

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Point displacement sampling of the outer diameter of both sides of the cable

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.