LSP067 · Display and imaging module assembly · Display and touch module
Partially reusable

Observation of laser spot emission at different exit pupil positions

Facing the AR optical waveguide test piece, the separation light point array comparison is used as the observation route, and the position and visible state of the exit point are planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceAR optical waveguide test piece
Measure routeARRAY·Separate spot array comparison
Ability GradingPartially reusable
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.

Business tasks and intended output

target audience
AR optical waveguide test piece: separation light spot array comparison
pseudo output
Exit point position and visible state
Applicable conditions
Brightness uniformity requires radiation and angle calibration
priority
General extension. Verification needs to be completed according to the listed optical conditions, calibration and samples.

Imaging input and algorithm routing

Imaging and device conditions

Separate and numberable multiple light spots, fixed receiving plane and field of view. Collimated lasers, imaging/projection targets and fixtures

ARRAY·Separate spot array comparison

Separate and numberable multiple light spots, fixed receiving plane and field of view

  • A102Multi-laser spot connected domain candidate extraction
  • A105Laser spot second moment and main axis diameter
  • A107Laser spot quality and usability diagnostics
  • A108One-to-one matching of multi-laser spot reference bits
  • A112Laser spot two-dimensional repeatability and coverage ellipse

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Partially reusable

Requires calibration, synchronization or integration

The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.

Gaps in this scenario:Point sequence numbering, local ROI, crosstalk and occlusion processing are required; A108 only matches by distance in the same coordinate system. Brightness uniformity requires radiation and angle calibration. Laser spots used for testing do not represent full image quality

Route-level gaps:Point sequence numbering, local ROI, crosstalk and occlusion processing are required; A108 only matches by distance in the same coordinate system

"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Verify point counts, match rates, and mismatches using known lattice and artificial defect/overlap/scrambling data. Standard image plane, angle table and imaging test chart are separately accepted

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S09 · Original factory/scientific research institution/original paper

Duma Beam Position and Optical Adjustment Application

Application categories for beam position, optical setup and spot shape

Verification date: 2026-10-24

View original public information →
LS-S17 · Original factory/scientific research institution/original paper

Holo/Or structured light principle

The principle of using known projection patterns and geometric deformations for measurement

Verification date: 2026-10-24

View original public information →
LS-S29 · Original factory/scientific research institution/original paper

Edmund collimation conditions

Relationship between source size, focal length and divergence angle

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Observation of laser spot emission at different exit pupil positions

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.