Duma Beam Position and Optical Adjustment Application
Application categories for beam position, optical setup and spot shape
Verification date: 2026-10-24
View original public information →For the focusable laser module, the spot shape and relative distribution are used as the observation route, and the focal position sequence and the minimum spot candidate are planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
Linear response imaging, fixed attenuation and background acquisition avoid saturation and ROI truncation. Wavelength-adapted cameras, attenuators and fixed near/far field fixtures
Linear response imaging, fixed attenuation and background acquisition to avoid saturation and ROI truncation
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
Existing light point positioning, quality diagnosis or statistical modules can be used as the main calculation basis; ROI, calibration, threshold and interface verification still need to be completed by device.
Gaps in this scenario:Pixel scale, background subtraction and dynamic range verification required; grayscale integration is not watts or joules. Focus search and propagation fitting need to be adapted. Pixel grayscale and optical power are calibrated separately
Route-level gaps:Pixel scale, background subtraction and dynamic range verification required; grayscale integration not watts or joules
"Reusable modules" only describe the relative development volume and do not constitute a commitment to accuracy, tempo, stability or delivery time.
Verify center, width and cutoff separately against a stand-alone beam analyzer or known spot pattern. Independent beam analyzer and temperature control/current recording cross-reference
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Application categories for beam position, optical setup and spot shape
Verification date: 2026-10-24
View original public information →Camera beam profile analysis and industrial laser diagnosis; power measurement requires special sensors
Verification date: 2026-10-24
View original public information →Relationship between source size, focal length and divergence angle
Verification date: 2026-10-24
View original public information →Focus return inspection of focusing mechanism
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357