Enterprise application areas D53

Infrared vision development services for data centers, communications, power supplies and computing equipment

Targeting equipment manufacturers, system integrators and enterprise R&D related to "data centers, communications, power and computing equipment", it provides infrared data evaluation, algorithm development, equipment/platform integration and test acceptance, covering 8 types of enterprise application scenarios.

Service scope and implementation plan

direction numberD53
Demand scenario8 items
main inputLWIR L2/L3; Macro LWIR/MWIR L2/L3;
Typical routeT03、T04、T05、T02、T19、T20

The project scope is determined based on samples, equipment, working conditions and written indicators; general modules, special models and multi-sensor integration are configured according to the evaluation results.

Application scenarios and development content

IR417

Server cabinet air inlet and outlet and hot spot monitoring

Minimum input and technical route
LWIR L2/L3;T03+T04
target output
Cabinet temperatures, hot and cold zones and trends
Implementation
Partially reusable
critical acceptance
Versus cabinet sensors/loads
IR418

CPU/GPU/acceleration card board-level thermal evaluation

Minimum input and technical route
Macro LWIR/MWIR L2/L3;T03+T05
target output
Device/heatsink temperature and transients
Implementation
Requires macro calibration
critical acceptance
Versus on-chip/thermocouple, temperature P95
IR419

PDU, UPS, battery and busbar connection hotspots

Minimum input and technical route
LWIR L2/L3;T04+T05
target output
Device/junction temperature and anomalies
Implementation
Partially reusable
critical acceptance
Compare with load/maintenance results
IR420

Cold aisle containment, air leakage and airflow organization assessment

Minimum input and technical route
LWIR L2/L3;T03+T05
target output
Hot and cold mixing zone and air outlet status
Implementation
Requires environmental sensing
critical acceptance
Compare with air volume/temperature point
IR421

Thermal abnormalities of liquid cooling pipelines, cold plates and quick connectors

Minimum input and technical route
LWIR L2/L3;T02+T05
target output
Uneven Cooling, Leak Candidates and Trends
Implementation
Required flow/pressure true value
critical acceptance
Compare with cooling system instrumentation
IR422

Base station RF power amplifier, power supply and feeder hotspots

Minimum input and technical route
LWIR L2/L3;T04+T05
target output
Component temperature rise and load correlation
Implementation
Partially reusable
critical acceptance
Compare with power/alarm/maintenance
IR423

Outdoor communication cabinet door seal, heating and cooling status

Minimum input and technical route
LWIR L2/L3;T03+T19
target output
Thermal distribution, door status and environmental events
Implementation
Partially reusable
critical acceptance
Compare with door sensor/air conditioner status
IR424

Computing equipment thermal imaging and telemetry combined capacity/fault analysis

Minimum input and technical route
L4;T05+T20
target output
Thermal status, telemetry correlation and exception sequencing
Implementation
Multi-source model required
critical acceptance
Time synchronization, correlation, fault hit rate

Information required before project evaluation

  • Target equipment/object, site conditions, business processes and follow-up actions to be taken
  • Infrared camera, lens, spectral band, installation distance, field of view, resolution and data interface
  • Original samples and collection parameters under normal, abnormal, boundary and interference conditions
  • Reference truth values and annotation specifications for temperatures, parts, states, or events
  • Target platform, network, interface, storage, latency and operating resource constraints
  • False positives, missed negatives, manual review, linkage, failure handling and acceptance thresholds

Implementation and delivery methods

  1. Project input confirmationCheck camera, spectral band, bit depth, SDK, environmental conditions, sample and acceptance true value.
  2. Sample verificationVerify key processing links, applicable conditions and abnormal working conditions, and determine the development scope and acceptance methods.
  3. Algorithm development and integrationImplement data parsing, algorithms, quality gating, interfaces and target platform deployment.
  4. Test acceptance and handoverRetest according to the agreed test set and target platform, and hand over the deliverables, test results and applicable conditions.
  • Requirements and technical solutions, input and output and interface field definitions
  • Algorithm library, model or SDK/API; delivery form is confirmed in the project plan
  • Sample program, parameter configuration, error status and calling instructions
  • Test set version, indicator definition, stratification results and failed sample records
  • Target platform adaptation, resource usage and running delay records
  • Version, dependencies, license, reproduction steps and applicable conditions description

Acceptance design

Each scenario establishes independent test cases according to "key acceptance". When sharing models across scenarios, results are reported separately for each scenario, distance, load, environment, and target size, supplemented by overall statistics.

When high-risk alarms or controls are involved, the algorithm output is used for review or linkage judgment; safety functions, regulatory responsibilities, and automatic disposal require separate design and acceptance.

Frequently Asked Questions for Enterprise Customers

Can I purchase directly based on one of the scenes?

Can be evaluated first as a separate work package. The formal scope should describe the device, data, target objects, environment, interfaces, delivery form, and acceptance thresholds.

Can it be started when there are no abnormal samples?

The data interface, normal baseline, acquisition plan and simulation/controlled test design can be completed first; the abnormal detection rate and fault classification effect can be evaluated after obtaining sufficient abnormal true values.

Can the algorithm directly trigger alarms or equipment actions?

Duration, deduplication, quality gating, manual review, communication failure and safety interlocking need to be designed based on business risks. High-risk actions should be activated after completion of independent safety mechanisms and on-site acceptance.

Project consultation

Define the Development Scope with Samples and Device Requirements

Infrared vision development services for data centers, communications, power supplies and computing equipment

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.