Infrared image algorithm development and equipment adaptation

Technical basis and risk boundary of infrared imaging project

Capability judgments for enterprise infrared projects require a combination of input data, physical conditions, test evidence, and usage risks. Equipment, data, verification methods and project conditions can be checked based on this before project approval.

Main risks and boundaries

  1. The pseudo-color image is not temperature data. Colors are generated from the color palette and current range, and the same color may represent different temperatures in different images.
  2. Ordinary thermal imaging does not automatically equal radiation thermometry. It is necessary to confirm whether the camera outputs radiometric data, calibration range and error conditions.
  3. Surface temperature is not equal to internal temperature. Battery core temperature, food core temperature, grain pile deep temperature and human core body temperature must be verified with corresponding true values.
  4. Reflections from metal, glass, water, and smooth surfaces can create false hot spots. Low emissivity targets should be compensated for emissivity and reflected apparent temperature.
  5. Thermal images generally cannot see through ordinary glass, walls, clothing, or physical ruins. Visible "heat trails" do not mean visible objects.
  6. NIR/SWIR mainly looks at the difference in reflection, transmission or absorption, not the normal temperature temperature chart. Active fill light also evaluates eye safety, uniformity and ambient light.
  7. SWIR/Hyperspectral component regression is highly dependent on sample, waveband, light source, temperature and laboratory truth. Independent batch external verification is required.
  8. Optical gas imaging must match gas absorption spectra and specialized filters. A visible gas plume does not mean that the gas has been identified, nor does it mean that the concentration or leak rate has been measured.
  9. Active thermal NDT defect depth and detection rates are dependent on material, thickness, excitation, sampling, and reference coupons. Composite drawings or individual samples cannot prove POD.
  10. AI enhancement and super-resolution may create textures or change borders. The measurement chain should retain the original data and the enhanced plots should not replace the original quantitative results.
  11. Medical, firefighting, equipment shutdown, law enforcement, and identification are high-risk uses that require independent regulatory, functional safety, deviation, and human review design.
  12. Public data is only suitable for algorithm baseline and reproduction verification, and cannot replace product domain acceptance of target equipment, lenses, installation distances, environments and business processes.

Inputs required to start the project

  • Camera brand, model, detector type, spectral band, resolution, pixel size, lens and field of view;
  • Whether it is radiation type, output format, bit depth, temperature matrix interface, SDK, range/gain file and NUC mode;
  • Whether there is a shutter, blackbody, external temperature reference source, infrared window and sync/trigger interface;
  • Target material, emissivity, surface condition, temperature range, distance, minimum target size and desired number of pixels;
  • Ambient temperature, humidity, wind, solar radiation, smoke, rain, fog and background reflection conditions;
  • Still images, continuous video, timestamps, equipment loads, process volumes and asset/part identification;
  • If it is dual light: internal and external parameters, time synchronization, resolution, focal length, field of view and installation stiffness of the two cameras;
  • If it is SWIR/hyperspectral: light source, white board, dark field, wavelength calibration, sample batch and laboratory true value;
  • If it is active thermal imaging: excitation type, power/timing, camera frame rate, sample material thickness and artificial defects;
  • If it is OGI: target gas, special filter spectrum segment, true flow value, wind speed, distance and background temperature difference;
  • If human/animal: ethics, consent, environmental stabilization time, ROI protocols, clinical/veterinary truth and data retention;
  • Written acceptance metrics, independent test sets, failure conditions, manual review processes, and linkage boundaries.

Public technical information

The following materials illustrate engineering conditions, measurement influencing factors, public data, and industry methodologies. Specific project indicators are based on target equipment, project data and test results under on-site conditions.

S01

Teledyne FLIR · Thermographic measurement techniques

Emissivity, reflected apparent temperature, distance, humidity and external optical parameters.

View original source →
S02

Teledyne FLIR · Infrared Imaging Radiometry Handbook

Radiation composition, temperature conversion and sources of error.

View original source →
S03

ISO · ISO 18434-1:2008 Condition monitoring and diagnostics of machines — Thermography

Thermal imaging procedures and compensation in machinery condition monitoring.

View original source →
S04

ASTM · E1933-14(2022) Emissivity measurement and compensation

Emissivity measurement and compensation.

View original source →
S05

ASTM · Nondestructive Testing Standards

Index of standards related to thermal imaging, flash thermography, vibration thermography and thermal imaging camera performance.

View original source →
S06

IEC · IEC TS 62446-3:2017 Outdoor infrared thermography for PV modules and plants

Photovoltaic outdoor infrared inspection conditions, equipment and reporting requirements.

View original source →
S07

IEA PVPS · Review on IR and EL Imaging for PV Field Applications

Field conditions and failure modes of photovoltaic IR/ELs.

View original source →
S08

NASA · Landsat Spectral Bands and Applications

NIR, SWIR and TIR bands and remote sensing purposes.

View original source →
S10

NIST · Nondestructive Testing and Sensor Technology for Concrete Structures

Thermal Imaging of Concrete NDT Principles, Advantages and Limitations.

View original source →
S11

NASA NTRS · Signal to Noise Studies on Thermographic Data with Fabricated Defects

Flash thermography and principal component processing.

View original source →
S12

Rajic · Principal component thermography for flaw contrast enhancement and depth characterization

One of the original research bases of PCT.

View original source →
S13

Teledyne FLIR · Optical Gas Imaging

Specific gases, dedicated filters and quantitative OGI conditions.

View original source →
S14

U.S. Department of Energy · AirBEM: Aerial Technology for Building Energy Auditing

Visible/infrared, drone and architectural models combined.

View original source →
S15

Hwang et al. · KAIST Multispectral Pedestrian Detection Benchmark

Aligned visible-thermal infrared pedestrian data.

View original source →
S16

Jia et al. · LLVIP: A Visible-infrared Paired Dataset for Low-light Vision

Low-light dual-light fusion and pedestrian detection data.

View original source →
S17

Teledyne FLIR · ADAS Thermal Dataset

Thermal infrared/visible light traffic target annotation data.

View original source →
S18

FDA · Improper Use of Thermal Imaging Devices

Limitations on the use of human body temperature screening.

View original source →
S20

USDA NIFA · Sensor-based Water Stress Assessment

Joint thermal imaging, multispectral and ground truth assessment of crop water stress.

View original source →
S21

U.S. Forest Service · Thermal Imaging

Wildfire infrared observations, smoke/cloud effects, and mixed cell limitations.

View original source →
S22

Hamamatsu Photonics · NIR and SWIR Questions and Answers

SWIR Food sorting, silicon wafer and hyperspectral applications.

View original source →
S23

IEC · IEC 80601-2-59 Screening thermographs

Basic safety and performance of thermal imaging cameras for human fever screening in controlled environments.

View original source →
S24

FDA · Thermogram No Substitute for Mammogram

Medical thermography is not a substitute for mammography screening.

View original source →
S25

NIST · IREX IX Part Two: Multispectral Iris Recognition

NIR Spectral and multispectral research on iris recognition.

View original source →
S26

NASA · Infrared Astronomy

The role of near/mid-infrared in dust obscuration and cold object observations.

View original source →

Rules for the use of evidence

Indicators involving performance, accuracy, frame rate, distance, detection rate or stability should also record the target device, data range, environment, version, statistical caliber and review results.

Project consultation

Define the Development Scope with Samples and Device Requirements

Technical basis and risk boundary of infrared imaging project

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.