Enterprise application areas D36

Industrial personnel occupational safety and behavioral infrared vision development services

For equipment manufacturers, system integrators and corporate R&D related to "industrial personnel operating safety and behavior", it provides infrared data evaluation, algorithm development, equipment/platform integration and test acceptance, covering 8 types of enterprise application scenarios.

Service scope and implementation plan

direction numberD36
Demand scenario8 items
main inputLWIR/RGB-LWIR L4;LWIR L3;LWIR L2/L3;L2/L5
Typical routeT07、T19、T03、T10、T16、T06、T20

The project scope is determined based on samples, equipment, working conditions and written indicators; general modules, special models and multi-sensor integration are configured according to the evaluation results.

Application scenarios and development content

IR281

Personnel approach monitoring in safe areas of high-temperature equipment

Minimum input and technical route
LWIR/RGB-LWIR L4;T07+T19
target output
People, heat sources, distances and risk events
Implementation
Requires spatial calibration
critical acceptance
Distance Error, Risk Recall, Delay
IR282

Personnel presence and fall detection in dark factories

Minimum input and technical route
LWIR L3;T07+T19
target output
People, postures, falls and stays
Implementation
Scenario data required
critical acceptance
Fall Recall, false alarm/hour
IR283

Monitoring of detention and departure of cold storage personnel

Minimum input and technical route
LWIR L3;T07+T19
target output
Personnel trajectory, detention and door status
Implementation
Business system required
critical acceptance
Event F1, occlusion recovery rate
IR284

Recording of heat exposure in furnace front, foundry and fire protection operations

Minimum input and technical route
LWIR L2/L3;T03+T07
target output
Personnel/equipment surface temperature and exposure time
Implementation
Security/privacy design required
critical acceptance
Comparison with wearable sensors; not equal to human body core temperature
IR285

Protective clothing insulation anomalies and heat penetration test

Minimum input and technical route
L2/L5;T10+T16
target output
Surface hot zones, temperature rise curves and anomalies
Implementation
Standard test required
critical acceptance
Comparison with standard thermal protection test
IR286

Thermal imaging aids for wearing gloves, masks and thermal insulation gear

Minimum input and technical route
NIR/LWIR L3/L4;T06+T07
target output
Equipment area and wearing candidates
Implementation
Dual optical data required
critical acceptance
Human-level Recall, long-range/occlusion layering
IR287

Joint tracking of personnel and high-temperature workpieces in the human-machine collaboration area

Minimum input and technical route
RGB-LWIR L4;T06+T19
target output
People, artifacts, trajectories, and conflict events
Implementation
Need system integration
critical acceptance
IDF1, distance error, event Recall
IR288

Thermal safety alarm evidence, manual review and linked gate control

Minimum input and technical route
L3/L4;T20
target output
Alarm, evidence fragment, review and linkage status
Implementation
Safety engineering required
critical acceptance
Missing negatives, false triggers, end-to-end delays; linkage requires independent security verification

Information required before project evaluation

  • Target equipment/object, site conditions, business processes and follow-up actions to be taken
  • Infrared camera, lens, spectral band, installation distance, field of view, resolution and data interface
  • Original samples and collection parameters under normal, abnormal, boundary and interference conditions
  • Reference truth values and annotation specifications for temperatures, parts, states, or events
  • Target platform, network, interface, storage, latency and operating resource constraints
  • False positives, missed negatives, manual review, linkage, failure handling and acceptance thresholds

Implementation and delivery methods

  1. Project input confirmationCheck camera, spectral band, bit depth, SDK, environmental conditions, sample and acceptance true value.
  2. Sample verificationVerify key processing links, applicable conditions and abnormal working conditions, and determine the development scope and acceptance methods.
  3. Algorithm development and integrationImplement data parsing, algorithms, quality gating, interfaces and target platform deployment.
  4. Test acceptance and handoverRetest according to the agreed test set and target platform, and hand over the deliverables, test results and applicable conditions.
  • Requirements and technical solutions, input and output and interface field definitions
  • Algorithm library, model or SDK/API; delivery form is confirmed in the project plan
  • Sample program, parameter configuration, error status and calling instructions
  • Test set version, indicator definition, stratification results and failed sample records
  • Target platform adaptation, resource usage and running delay records
  • Version, dependencies, license, reproduction steps and applicable conditions description

Acceptance design

Each scenario establishes independent test cases according to "key acceptance". When sharing models across scenarios, results are reported separately for each scenario, distance, load, environment, and target size, supplemented by overall statistics.

When high-risk alarms or controls are involved, the algorithm output is used for review or linkage judgment; safety functions, regulatory responsibilities, and automatic disposal require separate design and acceptance.

Frequently Asked Questions for Enterprise Customers

Can I purchase directly based on one of the scenes?

Can be evaluated first as a separate work package. The formal scope should describe the device, data, target objects, environment, interfaces, delivery form, and acceptance thresholds.

Can it be started when there are no abnormal samples?

The data interface, normal baseline, acquisition plan and simulation/controlled test design can be completed first; the abnormal detection rate and fault classification effect can be evaluated after obtaining sufficient abnormal true values.

Can the algorithm directly trigger alarms or equipment actions?

Duration, deduplication, quality gating, manual review, communication failure and safety interlocking need to be designed based on business risks. High-risk actions should be activated after completion of independent safety mechanisms and on-site acceptance.

Project consultation

Define the Development Scope with Samples and Device Requirements

Industrial personnel occupational safety and behavioral infrared vision development services

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.

Phone: 13910119357
xuzhiyang0928@gmail.com

The information filled in will only be used for evaluation and contact for this project. Please do not submit unauthorized personal information or sensitive data.