Enterprise Application Area D25

Infrared vision development services for HVAC, heating, ventilation and indoor thermal environments

For "HVAC, heating, ventilation and indoor thermal environment" related equipment manufacturers, system integrators and enterprise R&D, it provides infrared data evaluation, algorithm development, equipment/platform integration and test acceptance, covering 8 types of enterprise application scenarios.

Service scope and implementation plan

direction numberD25
Demand scenario8 items
main inputLWIR L2/L3; LWIR L2/L4;
Typical routeT03、T05、T02、T04、T15、T20

The project scope is determined based on samples, equipment, working conditions and written indicators; general modules, special models and multi-sensor integration are configured according to the evaluation results.

Application scenarios and development content

IR193

Return air inlet temperature distribution and short-circuit return air candidates

Minimum input and technical route
LWIR L2/L3;T03+T05
target output
Outlet temperatures, thermal plumes and anomaly patterns
Implementation
Partially reusable
critical acceptance
Compare with air volume/temperature sensor
IR194

Air duct insulation defects and air leakage heat traces

Minimum input and technical route
LWIR L2/L3;T02
target output
Exception areas and review points
Implementation
Partially reusable
critical acceptance
Compare with pressure/smoke/air volume
IR195

Frosting, clogging and uneven heat transfer of air conditioning coils

Minimum input and technical route
LWIR L2/L3;T03+T04
target output
Coil temperature, frost zone and status
Implementation
Need working condition data
critical acceptance
Versus pressure/refrigerant/labor inspection
IR196

Radiators, radiators and hydraulic imbalances

Minimum input and technical route
LWIR L2/L3;T03+T05
target output
Surface temperature distribution and imbalance candidates
Implementation
Partially reusable
critical acceptance
Versus flow/valve position, zone repeatability
IR197

Cooling tower water distribution and heat exchange abnormalities

Minimum input and technical route
LWIR L2/L4;T03+T04
target output
Hot areas, uneven water distribution and fan status
Implementation
Required environment model
critical acceptance
Compare with temperature difference/flow rate/maintenance
IR198

Indoor uneven heating and cooling and thermal comfort space diagram

Minimum input and technical route
LWIR L2/L4+ environment sensing;T15
target output
Surface temperature, personnel area thermal environment and changes
Implementation
Architectural model required
critical acceptance
Compare with air/radiant temperature measurements; do not judge comfort by thermal imaging alone
IR199

Fresh air, exhaust air and heat recovery performance screening

Minimum input and technical route
LWIR L2/L3;T05
target output
Inlet and outlet temperature fields and efficiency candidates
Implementation
Flow/temperature and humidity data required
critical acceptance
Comparison with standard efficiency calculations
IR200

HVAC equipment group abnormal thermal status ranking

Minimum input and technical route
L2/L3;T05+T20
target output
Equipment baselines, outliers, and maintenance checklists
Implementation
Partially reusable
critical acceptance
Working condition normalization and sorting stability

Information required before project evaluation

  • Target equipment/object, site conditions, business processes and follow-up actions to be taken
  • Infrared camera, lens, spectral band, installation distance, field of view, resolution and data interface
  • Original samples and collection parameters under normal, abnormal, boundary and interference conditions
  • Reference truth values and annotation specifications for temperatures, parts, states, or events
  • Target platform, network, interface, storage, latency and operating resource constraints
  • False positives, missed negatives, manual review, linkage, failure handling and acceptance thresholds

Implementation and delivery methods

  1. Project input confirmationCheck camera, spectral band, bit depth, SDK, environmental conditions, sample and acceptance true value.
  2. Sample verificationVerify key processing links, applicable conditions and abnormal working conditions, and determine the development scope and acceptance methods.
  3. Algorithm development and integrationImplement data parsing, algorithms, quality gating, interfaces and target platform deployment.
  4. Test acceptance and handoverRetest according to the agreed test set and target platform, and hand over the deliverables, test results and applicable conditions.
  • Requirements and technical solutions, input and output and interface field definitions
  • Algorithm library, model or SDK/API; delivery form is confirmed in the project plan
  • Sample program, parameter configuration, error status and calling instructions
  • Test set version, indicator definition, stratification results and failed sample records
  • Target platform adaptation, resource usage and running delay records
  • Version, dependencies, license, reproduction steps and applicable conditions description

Acceptance design

Each scenario establishes independent test cases according to "key acceptance". When sharing models across scenarios, results are reported separately for each scenario, distance, load, environment, and target size, supplemented by overall statistics.

When high-risk alarms or controls are involved, the algorithm output is used for review or linkage judgment; safety functions, regulatory responsibilities, and automatic disposal require separate design and acceptance.

Frequently Asked Questions for Enterprise Customers

Can I purchase directly based on one of the scenes?

Can be evaluated first as a separate work package. The formal scope should describe the device, data, target objects, environment, interfaces, delivery form, and acceptance thresholds.

Can it be started when there are no abnormal samples?

The data interface, normal baseline, acquisition plan and simulation/controlled test design can be completed first; the abnormal detection rate and fault classification effect can be evaluated after obtaining sufficient abnormal true values.

Can the algorithm directly trigger alarms or equipment actions?

Duration, deduplication, quality gating, manual review, communication failure and safety interlocking need to be designed based on business risks. High-risk actions should be activated after completion of independent safety mechanisms and on-site acceptance.

Project consultation

Define the Development Scope with Samples and Device Requirements