Equipment Projects and Development Scope
The following projects can be broken down into visual subsystems or complete machine prototypes within an agreed range. First confirm the existing core components, samples and target outputs, and then determine the development content of circuits, controls, structures, algorithms and software.
Light field camera measurement and refocusing terminal development
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Commercial light field camera SDK, raw data, refocus or depth interface and task software
- Project Inputs
- Commercial light field cameras, SDK licenses and reference scenes
Related Engineering Services
Supporting development of digital holographic quantitative phase analysis equipment
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Customer holographic imaging systems, data acquisition, phase recovery and quantitative results
- Project Inputs
- Off-the-shelf opto-mechanical systems, original holograms and reference volumes
Related Engineering Services
Fourier stack microscopy imaging software development
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Customer-ready angle acquisition system, multi-image arrangement, reconstruction and error analysis
- Project Inputs
- Imaging system, angle data and reference sample available
Related Engineering Services
Development of light sheet microscopy acquisition control subsystem
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Finished microscopy system, camera and scan synchronization, volume data and task scheduling
- Project Inputs
- Finished scanning light machine, camera trigger and control permissions
Related Engineering Services
Development of fluorescence lifetime imaging data analysis workstation
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Commercial system data, timing or decay fits, parametric plots, and research reports
- Project Inputs
- Instrument data formats, response functions, and reference samples
Related Engineering Services
Raman mapping imaging control and analysis terminal development
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Commercial spectrometers and scanning stages, position spectrum correlation, mapping and results software
- Project Inputs
- Commercial systems, control APIs, standards and spectra
Related Engineering Services
Angle-resolved reflection and BRDF test supporting development
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Customer-ready angular optics, position acquisition, calibration and reflection results software
- Project Inputs
- Finished optical, angular position and reference samples
Related Engineering Services
Supporting development of imaging ellipsometry data analysis equipment
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Commercially available polarizing optical systems, multi-state acquisition, model inversion and parametric plots
- Project Inputs
- System calibration, material models and standard samples
Related Engineering Services
Development of industrial object imaging colorimetry equipment
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Commercial measurement cameras, color calibration, area colorimetry and batch comparison
- Project Inputs
- Reference instruments, lighting conditions and standard color samples
Related Engineering Services
Shutter timing and motion imaging verification equipment development
- Development Scope
- Customer-ready timing targets and motion stages, acquisition, shutter timing and distortion measurements
- Project Inputs
- Time targets, motion references and camera mockups
Related Engineering Services
Development of joint calibration equipment for frame and event cameras
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Two types of cameras, unified time events, external participation in time difference solution and verification
- Project Inputs
- Finished camera, observable target and time reference
Related Engineering Services
Supporting development of spectral reflection film measurement equipment
The measurement method and equipment interfaces require an initial technical assessment.
- Development Scope
- Commercial measurement cores, positional sampling, spectral model fitting and thickness distribution
- Project Inputs
- Finished optical, material models and standard film samples
Related Engineering Services
Responsibilities and Deliverables
| Development Stage | Deliverables | Items to Confirm |
|---|
| Requirements and system interfaces | Equipment tasks, inputs and outputs, interfaces and test requirements | Scope of responsibility for customer's existing systems and supplier components |
| Design and software development | Agreed circuitry, structure, firmware, algorithm or application | Actual design scope, source file rights and third-party licenses |
| Prototype and engineering joint debugging | Agreed configured prototype, parameters, construction and installation information | Number of prototypes, institutional conditions and on-site joint debugging arrangements |
| Validation and technical handover | Configuration list, test records, problem handling and usage instructions | Reference methods, judgment standards and subsequent maintenance scope |
Verification and Acceptance
Review the raw data, instrument response, physical model and reference samples before agreeing which quantities can be reconstructed, fitted or measured. Report model residuals separately from measurement errors. Responsibilities for specialist optomechanical and excitation systems are agreed separately.
Define the samples, target configuration, reference values, operating conditions and acceptance method before testing. Retain normal results, failure cases, version information, known limitations and retest records in the delivery documentation.
Enterprise Project Questions
With only off-the-shelf instruments or cameras, can software and interface development be commissioned?
A project can be limited to acquisition, control interfaces, algorithms or application software for an existing device. Provide the model, protocol or SDK, sample data and access rights so that the available functions can be checked first.
Does device development include all mechanical, optical and manufacturing work?
The project documents define each development responsibility. Precision motion, specialist optics, excitation, radiation sources and other core systems may be supplied by the customer or a specialist vendor. Prototype development and volume manufacturing are agreed separately.
How Are Acceptance Criteria Defined for These Equipment Projects?
Review the raw data, instrument response, physical model and reference samples before agreeing which quantities can be reconstructed, fitted or measured. Report model residuals separately from measurement errors. Responsibilities for specialist optomechanical and excitation systems are agreed separately.
Can design materials and maintainable source code be delivered at the same time?
Agree which circuit files, mechanical drawings, firmware, algorithms, software and build instructions will be delivered during requirements definition. Check third-party licenses and define delivery rights and scope in the project documents.
Project Enquiry
Provide Equipment and Sample Information to Define the Development Scope
Computational Imaging and Scientific Instrument Integration Development
Please describe the purpose of the equipment, existing systems, cameras and interfaces, target output, reference samples, prototype quantity and design data delivery requirements.
Phone: 13910119357