Color, texture and statistical classification
White balance and color-chart calibration → Lab/Delta E 2000 → LBP/GLCM/Gabor features → SVM or random forest
JIVISION offers project development and technical assessment for Spark, Arc, Welding-Arc and Abnormal-Flash Recognition. Scope: Spark/arc/flash regions, frequency, duration and equipment associations.
Spark/arc/flash regions, frequency, duration and equipment associations
Separate normal welding from abnormal arcing using equipment state; test frame rate and triggering because saturation can hide brief events.
These are candidate implementation paths. Establish a baseline on real samples, then select or combine methods for imaging, speed and deployment constraints. Model names do not imply measured project results.
White balance and color-chart calibration → Lab/Delta E 2000 → LBP/GLCM/Gabor features → SVM or random forest
RT-DETR, RTMDet, YOLOX, PP-YOLOE or rotated-box detection → non-maximum suppression and confidence thresholds → task rules
Shi-Tomasi/FAST features → LK, Farneback or DIS flow; alternatively TAPIR/TAPNext/RAFT → occlusion and drift handling
Detection and tracking → polygons, crossing, distance, time-to-collision, dwell and hysteresis rules → event state machine
Provide camera layouts, authorized video, target sizes, day/night samples, region/event definitions, concurrent streams, alert-review workflows and retention periods.
Result schema, algorithm or processing configuration, example outputs and evaluation records for: Spark/arc/flash regions, frequency, duration and equipment associations. Software format and source-code scope are agreed in the contract.
Specify input formats, output fields, coordinates/units, error states, versions and invocation methods. Define review and failure handling. The statement of work determines the exact scope of source code, executables, model files or analysis reports.
Event recall; false calls per day; shortest event duration
Evaluate events rather than only frames: misses, false alerts per hour, duration error, alert latency and recovery after occlusion. Include empty scenes and hard negatives.
These are measures to agree and test, not achieved-performance claims. Freeze samples, reference truth, thresholds and hardware/software versions before acceptance; report subgroup results and failures, identifying under-sampled conditions as uncovered.
Agree targets, stations, inputs and responsibilities in a statement of work, separating required and excluded conditions.
Use representative samples to test critical risks, document feasibility/failures and scope the next-stage estimate.
Implement agreed functions and interfaces with configuration/change records; use offline replay before authorized device or site integration.
Retest against individual measures and hand over contracted artifacts with known limits; manage maintenance, expansion and changeovers as subsequent work packages.
Use data minimization, anonymization and access controls as needed. Do not infer sensitive traits, emotions or medical status from appearance; review alerts and retain existing safety measures.
Candidate technologies are not license clearance. Check code, model weights, training data and dependency versions separately. Replace, license or exclude components unsuitable for the intended commercial delivery. Customer data is not used for public training by default.
Spark/arc/flash regions, frequency, duration and equipment associations. Deliverables: Result schema, algorithm or processing configuration, example outputs and evaluation records for: Spark/arc/flash regions, frequency, duration and equipment associations. Software format and source-code scope are agreed in the contract.
Separate normal welding from abnormal arcing using equipment state; test frame rate and triggering because saturation can hide brief events.
Task-specific measures: Event recall; false calls per day; shortest event duration. Evaluate events rather than only frames: misses, false alerts per hour, duration error, alert latency and recovery after occlusion. Include empty scenes and hard negatives.
After reviewing samples for spark/arc/flash regions, frequency, duration and equipment associations, equipment conditions and interfaces, scope validation, development, deployment and acceptance separately. Data coverage, site changes and delivery rights affect the estimate; no fixed performance or schedule is promised before assessment.
Service ID: E37 · Spark, Arc, Welding-Arc and Abnormal-Flash Recognition
Describe available samples, equipment and target measures. Agree confidentiality and permissions before transferring sensitive or personal data through an approved channel.
+86 13910119357