Laser and structured-light triangulation
Steger/Hessian laser extraction or phase/Gray-code decoding → phase unwrapping where applicable → triangulation
JIVISION offers project development and technical assessment for Dispensing, Potting and Solder-Volume Measurement. Scope: Dispensed bead width, height, section area, volume and continuity.
Dispensed bead width, height, section area, volume and continuity
Measure the substrate or use an explicit substrate model; reflective liquids and translucent adhesive may not yield valid depth.
These are candidate implementation paths. Establish a baseline on real samples, then select or combine methods for imaging, speed and deployment constraints. Model names do not imply measured project results.
Steger/Hessian laser extraction or phase/Gray-code decoding → phase unwrapping where applicable → triangulation
Voxel sampling, normals and FPFH → RANSAC or TEASER++ initialization → ICP/GICP/NDT refinement → geometric analysis
Provide drawings/datums, range and tolerances, traceable references, surface materials, working distance, camera arrangement, calibration conditions and cycle time.
Result schema, algorithm or processing configuration, example outputs and evaluation records for: Dispensed bead width, height, section area, volume and continuity. Software format and source-code scope are agreed in the contract.
Specify input formats, output fields, coordinates/units, error states, versions and invocation methods. Define review and failure handling. The statement of work determines the exact scope of source code, executables, model files or analysis reports.
Volume/section error; minimum interruption; repeatability
Distinguish resolution, absolute error and repeatability. Compare independent references across the working range, record calibration residuals and environmental/pose changes, and assess the measurement system where required.
These are measures to agree and test, not achieved-performance claims. Freeze samples, reference truth, thresholds and hardware/software versions before acceptance; report subgroup results and failures, identifying under-sampled conditions as uncovered.
Agree targets, stations, inputs and responsibilities in a statement of work, separating required and excluded conditions.
Use representative samples to test critical risks, document feasibility/failures and scope the next-stage estimate.
Implement agreed functions and interfaces with configuration/change records; use offline replay before authorized device or site integration.
Retest against individual measures and hand over contracted artifacts with known limits; manage maintenance, expansion and changeovers as subsequent work packages.
Pixel resolution is not measurement accuracy. Include occlusion, reflections, vibration and thermal drift in the error budget; confirm statutory metrology obligations separately.
Candidate technologies are not license clearance. Check code, model weights, training data and dependency versions separately. Replace, license or exclude components unsuitable for the intended commercial delivery. Customer data is not used for public training by default.
Dispensed bead width, height, section area, volume and continuity. Deliverables: Result schema, algorithm or processing configuration, example outputs and evaluation records for: Dispensed bead width, height, section area, volume and continuity. Software format and source-code scope are agreed in the contract.
Measure the substrate or use an explicit substrate model; reflective liquids and translucent adhesive may not yield valid depth.
Task-specific measures: Volume/section error; minimum interruption; repeatability. Distinguish resolution, absolute error and repeatability. Compare independent references across the working range, record calibration residuals and environmental/pose changes, and assess the measurement system where required.
After reviewing samples for dispensed bead width, height, section area, volume and continuity, equipment conditions and interfaces, scope validation, development, deployment and acceptance separately. Data coverage, site changes and delivery rights affect the estimate; no fixed performance or schedule is promised before assessment.
Service ID: B20 · Dispensing, Potting and Solder-Volume Measurement
Describe available samples, equipment and target measures. Agree confidentiality and permissions before transferring sensitive or personal data through an approved channel.
+86 13910119357