Candidate processing workflow
Laser-line extraction or structured-light/stereo depth → plane fitting → height/profile calculation
JIVISION offers project development and technical assessment for Gap, Flushness, Height, Step and Warpage Measurement. Scope: Z-direction geometry not reliably resolved by 2D images.
Z-direction geometry not reliably resolved by 2D images
Define datum planes and height direction; test reflective, transparent and dark surfaces, and flag invalid depth instead of reporting filled values as measured.
These are candidate implementation paths. Establish a baseline on real samples, then select or combine methods for imaging, speed and deployment constraints. Model names do not imply measured project results.
Laser-line extraction or structured-light/stereo depth → plane fitting → height/profile calculation
Provide drawings/datums, range and tolerances, traceable references, surface materials, working distance, camera arrangement, calibration conditions and cycle time.
3D calibration, point-cloud processing, measurement software and error assessment
Specify input formats, output fields, coordinates/units, error states, versions and invocation methods. Define review and failure handling. The statement of work determines the exact scope of source code, executables, model files or analysis reports.
Depth MAE/P95; invalid-point rate; repeatability; material coverage
Distinguish resolution, absolute error and repeatability. Compare independent references across the working range, record calibration residuals and environmental/pose changes, and assess the measurement system where required.
These are measures to agree and test, not achieved-performance claims. Freeze samples, reference truth, thresholds and hardware/software versions before acceptance; report subgroup results and failures, identifying under-sampled conditions as uncovered.
Agree targets, stations, inputs and responsibilities in a statement of work, separating required and excluded conditions.
Use representative samples to test critical risks, document feasibility/failures and scope the next-stage estimate.
Implement agreed functions and interfaces with configuration/change records; use offline replay before authorized device or site integration.
Retest against individual measures and hand over contracted artifacts with known limits; manage maintenance, expansion and changeovers as subsequent work packages.
Pixel resolution is not measurement accuracy. Include occlusion, reflections, vibration and thermal drift in the error budget; confirm statutory metrology obligations separately.
Candidate technologies are not license clearance. Check code, model weights, training data and dependency versions separately. Replace, license or exclude components unsuitable for the intended commercial delivery. Customer data is not used for public training by default.
Z-direction geometry not reliably resolved by 2D images. Deliverables: 3D calibration, point-cloud processing, measurement software and error assessment
Define datum planes and height direction; test reflective, transparent and dark surfaces, and flag invalid depth instead of reporting filled values as measured.
Task-specific measures: Depth MAE/P95; invalid-point rate; repeatability; material coverage. Distinguish resolution, absolute error and repeatability. Compare independent references across the working range, record calibration residuals and environmental/pose changes, and assess the measurement system where required.
After reviewing samples for z-direction geometry not reliably resolved by 2d images, equipment conditions and interfaces, scope validation, development, deployment and acceptance separately. Data coverage, site changes and delivery rights affect the estimate; no fixed performance or schedule is promised before assessment.
Service ID: B02 · Gap, Flushness, Height, Step and Warpage Measurement
Describe available samples, equipment and target measures. Agree confidentiality and permissions before transferring sensitive or personal data through an approved channel.
+86 13910119357