Hamamatsu PSD Technical Notes
Light point position, triangular ranging and position-sensitive detection principles; PSD hardware performance is not transferred to camera implementation
Verification date: 2026-10-24
View original public information →Facing the still liquid tank, using the reflection optical lever angle as the observation route, the liquid surface inclination angle candidate is intended to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
Fix the incident light and reflector, and calibrate the corresponding relationship between the camera/receiving screen and the angle stage. Transparent flow channel or liquid surface reflection light path, temperature and geometric reference
Fix the incident light and reflector, and calibrate the corresponding relationship between the camera/receiving screen and the angle stage
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.
Gaps in this scenario:Optical lever geometry, reflection double angle relationship and incident point movement compensation are required; mirror angle and target translation must be separated. Liquid level fluctuations render the single-point method ineffective and require gating. Liquid surface inclination, refraction and target translation need to be designed with identifiable optical paths
Route-level gaps:Optical lever geometry, reflection double angle relationship and incident point movement compensation are required; mirror angle and target translation must be separated
"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.
Use an independent angle stage/autocollimator to conduct bidirectional and multi-attitude tests, and report the angle error and return difference. Standard refractive fluid, liquid level angle/height table cross test
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Light point position, triangular ranging and position-sensitive detection principles; PSD hardware performance is not transferred to camera implementation
Verification date: 2026-10-24
View original public information →The principle of probe beam deflection caused by refractive index gradient
Verification date: 2026-10-24
View original public information →Active point triangulation, scanned geometry and error propagation
Verification date: 2026-10-24
View original public information →Reflection point observation of slightly tilted free liquid surface
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357