Micro-Epsilon Laser Triangulation Principle
Transmitting, receiving imaging and distance measurement after calibration
Verification date: 2026-10-24
View original public information →Facing the filling valve assembly, the point laser triangular displacement is used as the observation route to output the valve stem stroke and return property. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
By fixing the laser emission axis and the receiving camera baseline, separable light spots can be formed on the target surface. Enclosed work station, stable reference and cleanable optical window
By fixing the laser emission axis and the receiving camera baseline, the target surface can form separable light spots.
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.
Gaps in this scenario:It is necessary to add point laser ray intersection or one-dimensional nonlinear distance calibration adaptation; A97 only has a linear area, and A21 is a laser plane interface. The flow rate needs to be calibrated separately by the flow meter. Measurement object is shape/device displacement, no inferences are made about composition, sterility or airtightness
Route-level gaps:It is necessary to add point laser ray intersection or one-dimensional nonlinear distance calibration adaptation; A97 is only in the linear area, and A21 is the laser plane interface
"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.
Use gauge blocks and stages to cover range and surface conditions and independently report physical error, repeatability, and speckle effects. Comparison of standard containers/thick sheets, contact gauges and independent defective samples
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Transmitting, receiving imaging and distance measurement after calibration
Verification date: 2026-10-24
View original public information →Industrial height, distance and position measurement categories
Verification date: 2026-10-24
View original public information →Displacement sensor combination thickness measurement; different measurement principles should be selected separately
Verification date: 2026-10-24
View original public information →Non-contact recording of valve stem opening and closing stroke
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357