Micro-Epsilon Laser Triangulation Principle
Transmitting, receiving imaging and distance measurement after calibration
Verification date: 2026-10-24
View original public information →Facing the soft-packed battery core fixture, using the bilateral/reference surface differential measurement as the observation route, the thickness and cycle time curves are planned to be output. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.
Synchronized bilateral point displacement heads, or single head with a known stable reference plane. Non-contact point ranging tooling and stable datum
Synchronous bilateral point displacement heads, or single head with a known stable reference surface
Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json
The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.
Gaps in this scenario:Point laser distance calibration, collinearity/synchronization and reference spacing models on both sides are required; the height of a single point is not directly equal to the thickness. Fixture loads and boundary conditions must be recorded. Shape displacement and electrochemical state are inspected separately
Route-level gaps:Point laser distance calibration, collinearity/synchronization and reference spacing models on both sides are required; the height of a single point is not directly equal to the thickness
"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.
Use standard thick slices and warped samples to compare, and change the inclination angle and motion phase to check the differential error. Cross-reference of standard parts, displacement tables and contact gauges
| Acceptance items | Evidence required for project confirmation | Current status |
|---|---|---|
| Inputs and samples | Real device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set aside | Not provided, waiting for project input |
| Magnitude and Error | Independent reference value, calibration record, error statistical caliber and mutual confirmation threshold | Not verified |
| Exceptions and boundaries | Anticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalities | To be defined |
| System integration | Interface, time synchronization, deployment platform, tempo, log, version and continuous running record | Not integrated |
The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.
Transmitting, receiving imaging and distance measurement after calibration
Verification date: 2026-10-24
View original public information →Industrial height, distance and position measurement categories
Verification date: 2026-10-24
View original public information →Displacement sensor combination thickness measurement; different measurement principles should be selected separately
Verification date: 2026-10-24
View original public information →Bilateral thickness test of compressed soft packages
Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.
Phone: 13910119357