LSP048 · Galvanometers and fast reflex mirrors · Scanning and precision motion optics
Partially reusable

Scanning field retest after lens replacement

Facing the galvanometer calibration tool, using two-dimensional command/target surface coordinate calibration as the observation route, it is planned to output the old-new mapping difference and the margin error. The page is for project evaluation and does not mean that the development has been completed or has been accepted on site.

Project Judgment Summary

Product/DeviceGalvanometer calibration tooling
Measure routeCAL · Two-dimensional command/target coordinate calibration
Ability GradingPartially reusable
Verification statusThe actual machine/product domain acceptance of this scenario has not been carried out
Scene nature:Similar potential application scenarios for laser spots. The potential application scenario has not yet been developed into a complete product system; the actual machine/product domain acceptance of this scenario has not been carried out. The actual product/product domain acceptance quantity in catalog statistics is 0.

Business tasks and intended output

target audience
Galvanometer calibration tool: two-dimensional command/target coordinate calibration
pseudo output
Difference between old and new mapping and retention error
Applicable conditions
Calibration plate height and temperature should be consistent
priority
General extension. Verification needs to be completed according to the listed optical conditions, calibration and samples.

Imaging input and algorithm routing

Imaging and device conditions

Cover the calibrated corresponding points and independent set-out points of the two-dimensional field of view, and fix the optical path and working plane. Calibration target, command log, camera timestamp and angle reference

CAL · Two-dimensional command/target coordinate calibration

Calibration corresponding points and independent set-out points covering the two-dimensional field of view, fixed optical path and working plane

  • A101Adaptive threshold laser spot grayscale centroid
  • A107Laser spot quality and usability diagnostics
  • A109Two-dimensional pixel to physical coordinate polynomial calibration
  • A110laser spot calibration mapping and covariance propagation
  • A112Laser spot two-dimensional repeatability and coverage ellipse

Existing algorithmic evidence:A101–A112 only complete analytical synthesis spot and controlled geometry verification; see laser_spot_benchmark.json

Current capabilities and capabilities to be supplemented

Partially reusable

Requires calibration, synchronization or integration

The light point detection front-end or timing statistics module can be reused, but the project still needs to add geometric calibration, time synchronization, motion compensation or equipment system integration.

Gaps in this scenario:Calibration acquisition, coordinate definition and verification are required; two-dimensional empirical mapping does not represent any three-dimensional or robot calibration. Calibration plate height and temperature should be consistent. Position observation and execution control must be independently accepted

Route-level gaps:Calibration acquisition, coordinate definition and verification are required; two-dimensional empirical mapping does not represent any three-dimensional or robot calibration

"Partially reusable" only describes the relative development volume and does not constitute a commitment to accuracy, tempo, stability or delivery time.

Verification methods and acceptance prerequisites

Separate calibration points and set-out points to check edge, back-and-forth, temperature and repeated clamping errors. Set aside points, steps and sweeps to verify delays and loss of lock

Acceptance itemsEvidence required for project confirmationCurrent status
Inputs and samplesReal device original frames, normal/abnormal samples, exposure and light path conditions, sample grouping and set asideNot provided, waiting for project input
Magnitude and ErrorIndependent reference value, calibration record, error statistical caliber and mutual confirmation thresholdNot verified
Exceptions and boundariesAnticipated handling of missed detections, false detections, overexposure, occlusion, reflection, out-of-view and communication abnormalitiesTo be defined
System integrationInterface, time synchronization, deployment platform, tempo, log, version and continuous running recordNot integrated

Evidence sources and citation boundaries

The source supports measurement principles or similar applications; the module combination, device and acceptance method in this scenario are engineering derivation, and product verification has not been completed.

LS-S13 · Original factory/scientific research institution/original paper

SCANLAB scanning field calibration

Test patterns, imaging measurements and field correction

Verification date: 2026-10-24

View original public information →
LS-S14 · Original factory/scientific research institution/original paper

Newport beam pointing system

Fast mirror and beam pointing control system categories

Verification date: 2026-10-24

View original public information →
LS-S15 · Original factory/scientific research institution/original paper

Newport fast reflex mirror and active beam stabilization technology

System principles of position drift, pointing drift and active compensation

Verification date: 2026-10-24

View original public information →
Source usage scope:The public information is used to support the measurement principle or the existence of similar applications, and does not prove that this scenario has been developed, deployed or accepted by Jishi Technology.
Project consultation

Define the Development Scope with Samples and Device Requirements

Scanning field retest after lens replacement

Please describe the task object, original picture or video, target indicators, device platform, interface and sample situation.