In the original industrial PC smoke project, the stage report for smoke_acceptance_model_v1 limits acceptance to the current dataset and fixed camera region. It identifies a small test set containing weakly labeled samples. Those findings do not establish detection quality at other sites or long-term stability.

Separate versions and sample scope

The public case also records later models, video reproductions and rule regression tests. Their versions, inputs and counting units differ from the original model stage report. Retain each version and sample scope. Do not combine results from different reports into a general metric for one model.

Retain night and new-site conditions

The original model card disables black-smoke color judgment in low light and returns unknown_night. The report requires target-site videos showing an absence of smoke, real black smoke, and interference from rain, fog or dust. Camera angle, resolution or detection-region changes require reconfiguration and evaluation. Continuous operation and recovery need separate records.

Evidence covered by this review

This review checks the original publication record, model card, stage report and public case. No additional model training, device tests, site sampling or long-duration verification were performed for this review. The original public case does not replace statutory monitoring equipment or third-party test findings. New-site acceptance requires actual inputs, configurations and intended use.

Source: Original industrial PC smoke detection case.